Conventional Beam Detector non-addressable infrared smoke sensor

Add to Cart
Conventional Beam Detector is a non-addressable infrared beam smoke detector which must be used together with a reflector. The number of reflector(s) to be used (one or four) depends on the distance from the detector.
Shop professional fire and burglar security alarm system at https://www.vedardsecurity.com/conventional-beam-detector-nonaddressable-infrared-smoke-sensor-p-20
Conventional Beam Detector (hereinafter called the detector) is a non-addressable infrared beam smoke detector, which must be used together with a reflector. The number of reflector(s) to be used (one or four) depends on the distance from the detector.
With excellent built-in microprocessor, the detector has strong ability of analysis and judgment. The detector can automatically carry out system adjustment, compensation of variation of ambient data, and judgment of fire and fault through fixed algorithm, and indicate these states by LED and signal output terminals. With new and reasonable design, attractive appearance, flexible adjustment and alignment method it’s easy to install and adjust. The sensitivity of the detector can be set through hand held programmer in field, decreasing the demand for cleanliness of field conditions, and enlarging application areas. The detector is applicable
to historical buildings, warehouses, large storages, shopping malls, leisure centers, exhibition halls, hotel lobbies, printing houses, clothing factories, museums and prisons etc, as well as places where slight smoke particles exist.
II Features
(1) Wide operating voltage range, big monitoring areas.
(2) Combination of the emitting and receiving part makes mounting easy and optical pathway accurate.
(3) Built-in microprocessor enables intelligent judgment of fire alarm and fault.
(4) The detector can calibrate automatically, which ensures that one person complete adjustment in short time. It’s also convenient to operate.
(5) Self-diagnosis function can monitor the inner fault.
(6) Automatic compensation for factors weakening received signals, such as dust contamination, positional excursion and ageing transmitter.
(7) It has passive output contacts for fire alarm and fault.
(8) Two sensitivity levels can be set in field.
(9) The detector’s optical pathway is designed with strong anti-interference ability.
(10) SMT processing technology.
(11) Attractive and decent appearance.
III Technical Specifications
(1) Power Voltage: 15VDC to 28VDC
(2) Power Current: Commission current›20mA
Standby current›12mA Alarm
current›22mA
(3) Fire Alarm and Fault Contact Output:
Fire Alarm Relay: Contact capacity 28V/2A, which is normally open in normal state
Page 1
HD106
Conventional Beam Detector Installation and Operation Manual and closed in fire alarm state.
Fault Relay: Contact capacity 28V/2A, which is normally open in normal state and closed in fault state.
(4) Angle of Adjusting: -6~+6
(5) Sensitivity Level:
Level 1: High sensitivity.
Level 2: Medium sensitivity.
(6) Indication of Detector State:
Commission: Green LED and Yellow LED are lit or flash in a certain way. See
details in Section VI Commission.
Normal monitoring state: Red LED flashes periodically.
Fire: Red LED constantly illuminates, and Yellow LED turns off. Fire alarm should
be cleared through powering up again.
Fault: Yellow LED constantly illuminates. The detector clears the fault
signal automatically if the condition causing the fault disappears.
Optical pathway obscured totally: the detector first gives fault signal and turns
on Yellow LED. 20s later, it alarms fire, illuminates Red LED and turns off Yellow
LED. Note: In this case, it does not mean there is a fire. After the obscuration
is removed, the detector clears fault signal automatically. Fire signal has to
be cleared by powering up the detector again.
(7) Operating Environment:
Temperature: -10?C to +50?C
Relative Humidity: 95%, non condensing
(8) Monitoring Area: Maximum monitoring area: 1400m 2
Maximum width: 14m
(9) Length of Optical Pathway: 8m to 100m
(10) Protection Level:
Under common environment, ingress protection rating is IP20.
Under special environment, ingress protection rating is IP66 through
glue-seal treatment.
(11) Dimension: length: 206mm width: 95mm thickness: 95mm
(12) Material and Color of Enclosure: ABS, gray
(13) Weight: 450g
(14) Mounting Hole Spacing: Spacing for embedding: 158mm
Spacings for surface mounting: 79mm to 96mm
    • UPC 704693094796
    • Brand TC fire alarm
    • Mfg Part # HD-106
Payment Methods
Shipping FEDEX, see description.
Payment Policy

Conditions of use

Hello and welcome to Vedard Alarm Systems Store. When you visit or shop at our alarm systems online store, you agree to these conditions.

Vedard Alarm Systems Company attempts to make product descriptions as accurate as possible. However, Vedard does not warrant that product descriptions are complete, current or error-free. If there is any doubts, please feel free to send email to check with us before buying.

Alarm Systems are devices of installation required before using. So, please make sure there is experienced alarm installer, electronic engineer, security service or experienced alarm user for the installation work after item is bought.

Vedard is not responsible for any wrong purchasing, non working of product with wrong configuration. Please make sure the wireless compatibility of buying wireless alarm accessories, wireless sensor with your exist wireless alarm system.

Cause of high rate international shipping charge for you and us, we do not accept fault goods return. But we offer 50% off new one sales for compensation. Product fault evidence is required.

You are welcome to post alarm systems reviews, comments on our website for your purchased products. And you are welcome to leave us a review at third party home security review website at home security reviews

Please make sure the content you posted is accurate, truthful and detailed to help visitors understanding our products and service well. Vedardalarm.com has the right to monitor and edit or remove any activity or content.

Shipping Policy

Thanks for shopping alarm systems at Vedard Alarm Systems Store.

Preparation for delivery usually takes 3~7 business days.

Generally, DHL shipping service is used for delivery and delivery time is 3~5 business days for most countries.

For package weight less than 2kgs, we may use air post service for delivery and delivery time may be 15~25 days.

Once an order was shipped, you will receive an email with tracking information.

Low customs value will be made to reduce your import tax in our commercial invoice.

If you have special requirement for shipping, please leave comment with us when you place the order. Thank you!

We can send email of alarm system manual for your preparing installing new technology alarm systems. Please contact us to send the alarm system manual.

If your ordered goods is happened out of stock or not available to be shipped, we will issue 100% refund immediately and send email notice to you.

Tracking No. will be provided.

We may use DHL, EMS, China post air mail, Swiss post air mail to deliver your parcel.

The parcel tracking Website is as below:

DHL

China post air mail

EMS

Swiss post air mail

Return/Exchange Policy

Your benefit is guaranteed while shopping at Vedard Security Systems Store.

We will refund you product rate once product shipped is found with fault.

But video, photo evidence should be provided and confirmed by our technical department. Refund application should be submitted within 7 days after products received. Refund application should be sent to service@vedardalarm.com and title with Refund order #.

Buyers are requested to read and know product carefully before buying. And you can ask question via our forum or e-mail. We don't accept wrong buying refund.

Buyer can select to return to us with product rate and freight rate refund. But return cost is charged by buyer.

Other Policies

Household alarms should be as necessary as household appliances. But home alarms are special products.It plays an important role in keeping the family safe.Therefore, the installation and use of family alarm should be based on the home environment safety needs and alarm installation requirements. For wireless alarm, different manufacturers, different brands of alarm equipment is not compatible. Therefore, before buying an alarm, carefully read the product description and understand the brand of the product to determine its wireless compatibility.
There are many kinds of alarms. Alarm manufacturers designed a variety of alarms for different users of different habits or environmental differences. Therefore, you can choose the most appropriate alarm according to your own security needs.
Before buying alarm equipment, you should understand the functions and characteristics of all kinds of alarms and your own security needs. If you have any questions, please contact the product seller. Professional alarm equipment sales will provide detailed product installation instructions, video demonstrations, and technical guidance.
The products details and technical support for vedardalarm security can be found at https://www.vedard.com/forum

Please Login or Register first before asking a question.
More from vedardalarm's Store