vedardalarm"s Store > Fire Alarm System

Fire Alarm Encoder Addressable fire alarm system

Add to Cart
a portable device for writing /reading address code of all intelligent fire alarm system, smoke detector, gas sensor, modules.
https://www.vedardalarm.com/fire-alarm-system-encoder-for-writing-reading-address-code-p-135
FT900 Coder is a portable device for writing /reading address code of all intelligent terminals our company produces, it’s a basic tool in the processes of device installing, debugging and servicing.
Features
1.Small size, shockproof and portable to take with;
2.Low power consumption, successive working duration
is up to 18 hours;
3.Support 2100/9000 intelligent terminal;
4.Automatically increase the code based on previous, improve the work efficiency;
5.Battery level can be checked;
6.Over-discharge protection is provided;
7.Short circuit protection is provided;
8.Charging indicator is designed;
9.Automatically enter power saving mode and power off in idle mode.
Technical Parameters
1.Built-in 1600mAh lithium battery;
2.External 24V/500mA DC can be used as direct work power supply or to charge the battery;
3.Working current: 15mA-170mA, standby current: 15mA;
4.Ambient temperature: -20C~60C, relative humidity: 5%~95%.
Appearance
Line-in: for attached connection line only to intelligent terminals such as detector, module or audible and
visual alarm;
Note: do NOT connect any other USB device!
24VDC port: for 24VDC/500mA power supply, inner is anode and outer ring is cathode.
Note: do NOT disconnect the power plug in working state!
Screen: displays battery level, prompts and address codes that have been read out and wait for writing.
Indictors: five indicators are designed to indicate the statuses of power, reading, writing, switching and charging (from left to right).
Power—green: the indicator turns on when it is powered on or there is an external power supply;
Reading—red: the indicator turns on when it’s in reading mode;
Writing—red: the indicator turns on when it’s in writing mode,and blinks when it’s in auto increase mode.
Switching—red: support 9000 bus terminal when it turns off; support 2100 bus terminal when it blinks.
Charging—green: the indicator turns on when it’s in charging state and turns off then it’s fully charged.
Keypad: 17 functional keys are designed including: select, delete, run, increase, decrease and numeric keys,
etc.
MENU: press this key to select the function of writing or reading; long press this key to enter the mode of
auto increase.
Delete: use in writing mode, press this key to delete the wrong code entering.
Run: write and read the address code of the intelligent terminals.
Increase: use in writing mode, press this key once to increase one level, long press this key to increase the address
code successively.
Decrease: use in writing mode, press this key once to decrease one level, long press this key to decrease the
address code successively.
Numeric Keys (0-9): enter the address code to be wrote
“*” : check battery level, not available when there is an external power supply.
“#” : press this key to switch between 2100 system mode and 9000 system mode.
Shockproof Sheath: reduce the impact with other hard objects, take it off when replacing battery.
Operations
1.ON/OFF
Long press “ON/OFF” key for 1 sec to power on the device with power indicator and writing indicator turned on, the screen displays numbers, the device enters working mode; when the device is in normal working mode or power saving mode, press this key to power off the device and all indicators are turned off; when there is an external power supply, the power indicator keeps turning on even in power-off state, at this moment, the user may re-start the device by pressing this key.
2.2100/9000 System Switching
It enters 9000 system as default when the device powers on; the user may press “#” key to switch to 2100 system, the screen displays “199” and the switching indicator blinks; further press “#” key to switch back to 9000 system, the screen displays “324” and the indicator turns off.
3.Battery Level
Press and hold “*” key to check the current battery level, 10 levels (1-10) are designed.
4.Writing
Connect terminal device by attached connection line and switch to applicable bus type. Press numeric keys to enter the address code, press Run key to code; if the writing process succeeds, the screen displays the address code and a beep sound can be heard; if the writing process fails, the screen blinks to display, and three beep sounds can be heard, at this moment the user is advised to check the system bus type and the connection of the device and terminal, then enter the address code and try to write again. press “Delete” key to delete wrong code entering.
5.Auto Increase of Address Code
Press and hold “Select” key for 2 secs, the writing indicator blinks, the system enters the mode of auto increase. When a correct address is wrote, the screen blinks to display the address; at this moment the user may disconnect the terminal device and the address increases automatically by one, press “Run” key to continue to write the address when installing the next terminal device;it’s unnecessary to enter address for later writing.
6.Reading
Connect terminal device by attached connection line and switch to applicable bus type. Press “Run” key to read out the address, if the reading process succeeds, the screen displays the address and a beep sound can be heard; if the reading process fails, the screen blinks to display, and three beep sounds can be heard, at this moment the user is advised to check the system bus type and the connection of the device and terminal, then read out the address again.
Other Functions
1.Bus short circuit detecting, in case of bus short circuit, the buzzer beeps twice a second till it recovers.
2.If no any operation is made within 1 minute, the screen would turn off and enter power saving mode; in this state, press any key to turn on (except ON/OFF).
3.If no any operation is made within 5 minutes, the system would automatically power off; pressing “ON/OFF” key can re-start the device.
VII. Assembling of Peripheral Devices
As figure 2, figure 3 and figure 4
1.Insert Φ3.5mm plug into the writing jack on the base frame of detector to make reading/writing
operation to the smoke detector and heat detector;
2.Insert Φ3.5mm plug into the writing jack of handhold alarm or fireplug to make reading/writing
operation;
3.5PIN plug is used for 2100 system module;
4.Insert 5PIN plug into the writing jack of handhold JTQ-BM-925T to make reading/writing operation;
5.4PIN plug is used for intelligent module and audio/visual alarm.
Precautions
1.Any other type of USB device is not allowed to connect with this product, otherwise it might damage your USB device.
2.Keep away from corrosive liquids and do not use in wet, hot environment and strong magnetic field.
3.Please use DC power adapter we provide, other types of power adapters might damage this product.
4.This coder is used only for the products our company produces; do NOT use it for those produced by others.
Check working compatible addressable fire alarm systems by click Fire alarms
    • UPC 782123753185
    • Brand CST
    • Mfg Part # FT-900
Payment Methods
Shipping USPS, $19.00
Payment Policy

Conditions of use

Hello and welcome to Vedard Alarm Systems Store. When you visit or shop at our alarm systems online store, you agree to these conditions.

Vedard Alarm Systems Company attempts to make product descriptions as accurate as possible. However, Vedard does not warrant that product descriptions are complete, current or error-free. If there is any doubts, please feel free to send email to check with us before buying.

Alarm Systems are devices of installation required before using. So, please make sure there is experienced alarm installer, electronic engineer, security service or experienced alarm user for the installation work after item is bought.

Vedard is not responsible for any wrong purchasing, non working of product with wrong configuration. Please make sure the wireless compatibility of buying wireless alarm accessories, wireless sensor with your exist wireless alarm system.

Cause of high rate international shipping charge for you and us, we do not accept fault goods return. But we offer 50% off new one sales for compensation. Product fault evidence is required.

You are welcome to post alarm systems reviews, comments on our website for your purchased products. And you are welcome to leave us a review at third party home security review website at home security reviews

Please make sure the content you posted is accurate, truthful and detailed to help visitors understanding our products and service well. Vedardalarm.com has the right to monitor and edit or remove any activity or content.

Shipping Policy

Thanks for shopping alarm systems at Vedard Alarm Systems Store.

Preparation for delivery usually takes 3~7 business days.

Generally, DHL shipping service is used for delivery and delivery time is 3~5 business days for most countries.

For package weight less than 2kgs, we may use air post service for delivery and delivery time may be 15~25 days.

Once an order was shipped, you will receive an email with tracking information.

Low customs value will be made to reduce your import tax in our commercial invoice.

If you have special requirement for shipping, please leave comment with us when you place the order. Thank you!

We can send email of alarm system manual for your preparing installing new technology alarm systems. Please contact us to send the alarm system manual.

If your ordered goods is happened out of stock or not available to be shipped, we will issue 100% refund immediately and send email notice to you.

Tracking No. will be provided.

We may use DHL, EMS, China post air mail, Swiss post air mail to deliver your parcel.

The parcel tracking Website is as below:

DHL

China post air mail

EMS

Swiss post air mail

Return/Exchange Policy

Your benefit is guaranteed while shopping at Vedard Security Systems Store.

We will refund you product rate once product shipped is found with fault.

But video, photo evidence should be provided and confirmed by our technical department. Refund application should be submitted within 7 days after products received. Refund application should be sent to service@vedardalarm.com and title with Refund order #.

Buyers are requested to read and know product carefully before buying. And you can ask question via our forum or e-mail. We don't accept wrong buying refund.

Buyer can select to return to us with product rate and freight rate refund. But return cost is charged by buyer.

Other Policies

Household alarms should be as necessary as household appliances. But home alarms are special products.It plays an important role in keeping the family safe.Therefore, the installation and use of family alarm should be based on the home environment safety needs and alarm installation requirements. For wireless alarm, different manufacturers, different brands of alarm equipment is not compatible. Therefore, before buying an alarm, carefully read the product description and understand the brand of the product to determine its wireless compatibility.
There are many kinds of alarms. Alarm manufacturers designed a variety of alarms for different users of different habits or environmental differences. Therefore, you can choose the most appropriate alarm according to your own security needs.
Before buying alarm equipment, you should understand the functions and characteristics of all kinds of alarms and your own security needs. If you have any questions, please contact the product seller. Professional alarm equipment sales will provide detailed product installation instructions, video demonstrations, and technical guidance.
The products details and technical support for vedardalarm security can be found at https://www.vedard.com/forum

Please Login or Register first before asking a question.
More from vedardalarm's Store